
9 Servicing
RPC-(1.5-6.0)FSN3 - Ceiling type
SMGB0099 rev.0 - 12/2016
289
9
9.5.10 Removal of the printed circuit board (PCB)
1 Open the air inlet grille downward according to
Air Filter and Air Inlet Grille”
2
Remove the electrical box and hook it on the flame at the lower
part of the unit according to
“9.5.4 Removal of the fan motor”
3
Remove 2 fixing screws for the electrical box cover and remove
it.
4
Remove the 6 holders fixing the indoor unit PCB. Pinch the
middle portion with a long-nose pliers and pull them out.
!
C A U T I O N
• Do not touch the electrical components on the PCB.
• Do not apply an excessive force to the PCB nor bend it. Otherwise, it
will lead to a PCB failure
• An incorrect position during installation may damage the PCB.
E-box cover
Holders
Holders
Holder
Middle
portion
Indoor
unit
PCB
Carefully remove the securing supports from the printed control board (PCB) by pressing carefully on the support tabs
with long-tipped pliers.
Nº
Part
1
Extended support part
2
PCB