9 Servicing
RPC-(3.0-6.0)FSN3E - Ceiling type
SMGB0099 rev.0 - 12/2016
276
9.4 RPC-(3.0-6.0)FSN3E - Ceiling type
9.4.1
Removal of the air filter
1
Press the buttons on the grille backwards.
2 Open the air inlet grille downwards.
3
Lift the button and remove the filter.
9.4.2 Removal of the side panel
1 Pull the side panel forwards.
Side panel
Hook at the front
part of the side
panel
2
Release the hook from the lower part of the panel.
3 Lift the side panel.
Hook at the upper part of the
side panel (2 sections)
Hook at the upper part of the
side panel (2 sections)
9.4.3 Removal of the air outlet grille
1 Remove the side panel in line with the instructions
“9.4.2 Removal of the side panel”
.
2
Remove the right shaft crank on the air louver.
3 Remove the four set screws from the louver and
remove it.
?
N O T E
The louver includes the linkage brackets.
Do not
hold this
louver
M4 screw
Fixing screws
Connector
Air deflection
Fixing screw
Air deflection
Bearing