ModBus Data Listing
Appendix B
B–40
C041
Overload level setting
R/W Sets the overload signal level
between 0% and 200% (from
0 to two times the rated
current of the inverter)
1124h
04388
0 to
20000
0.01 %
C042
Frequency arrival
setting for acceleration
R/W Sets the frequency arrival
setting threshold for the
output frequency during
acceleration, range is 0.0 to
400.0 Hz
1126h
04390 0 to 4000
*1
0.1 Hz
C043
Arrival frequency
setting for deceleration
R/W Sets the frequency arrival
setting threshold for the
output frequency during
deceleration, range is 0.0 to
400.0 Hz
1128h
04392 0 to 4000
0.1 Hz
C044
PID deviation level
setting
R/W Sets the allowable PID loop
error magnitude (absolute
value), SP - PV, range is 0.0 to
100%, resolution is 0.1%
1129h
04393 0 to 1000
0.1 %
C052
PID FBV function high
limit
R/W When the PV exceeds this
value, the PID loop turns OFF
the PID Second Stage Output,
range is 0.0 to 100.0%
112Eh
04398 0 to 1000
0.1 %
C053
PID FBV function low
limit
R/W When the PV goes below this
value, the PID loop turns ON
the PID Second Stage Output,
range is 0.0 to 100.0%
112Fh
04399 0 to 1000
0.1 %
C071
Communication speed
selection
—
NOTE: These network
settings are not accessible to
ModBus. Use the inverter
keypad or digital operator to
1138h
04408
—
—
C072
Node allocation
—
1139h
04409
—
—
C074
Communication parity
selection
—
113Bh 04411
—
—
C075
Communication stop bit
selection
—
113Ch 04412
—
—
C076
Communication error
select
—
113Dh 04413
—
—
C077
Communication error
time-out
—
113Eh
04414
—
—
C078
Communication wait
time
—
113Fh
04415
—
—
“C” Group Intelligent Terminal Functions
Func.
Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.