Dynamic Braking
Motor Control
Accesso
ri
es
5–6
Use one BRD–E2 braking unit for the braking torque listed in the following table.
Note the column meanings in the tables:
• Column “A” = Average braking torque from 60 Hz to 3 Hz.
• Column “B” = Average braking torque from 120 Hz to 3 Hz
Connect a second braking unit in parallel for additional braking torque listed in the
following table.
L200
2
Inverter 200V Models
Braking Torque with BRD–E2 Braking Unit
Model Number
HP
Braking
torque
without
braking unit
Using built-in
resistor only
External resistor added
HRB1
HRB2
HRB3
A
B
A
B
A
B
A
B
002NFE(F)2/NFU2
1/4
50%
150%
120%
004NFE(F)2/NFU2
1/2
50%
150%
120%
005NFE(F)2/NFU2
3/4
50%
150%
120%
007NFE(F)2/NFU2
1
50%
100%
80%
150%
120%
011NFE(F)2/NFU2
1.5
50%
60%
60%
100%
80%
015NFE(F)2/NFU2
2
50%
50%
50%
100%
80%
022NFE(F)2/NFU2
3
20%
50%
50%
100%
80%
037LFU2
5
20%
40%
40%
60%
60%
100%
100%
150%
120%
055LFU2
7.5
20%
30%
30%
50%
50%
70%
70%
100%
80%
075LFU2
10
20%
20%
20%
40%
40%
50%
50%
80%
80%
L200
2
Inverter 200V Models
Braking Torque with TWO (2) BRD–E2 Braking Units
Model Number
HP
Braking
torque
without
braking unit
Using built-in
resistor only
External resistor added
HRB1
HRB2
HRB3
A
B
A
B
A
B
A
B
002NFE(F)2/NFU2
1/4
50%
150%
120%
004NFE(F)2/NFU2
1/2
50%
150%
120%
005NFE(F)2/NFU2
3/4
50%
150%
120%
007NFE(F)2/NFU2
1
50%
150%
120%
011NFE(F)2/NFU2
1.5
50%
100%
80%
015NFE(F)2/NFU2
2
50%
100%
80%
022NFE(F)2/NFU2
3
20~40%
70%
70%
150%
120%
037LFU2
5
20~40%
50%
50%
110%
90%
055LFU2
7.5
20%
30%
30%
80%
80%
100%
100%
150%
150%
075LFU2
10
20%
30%
30%
60%
60%
80%
80%
100%
100%