L200
2
Inverter
Appendix B
B–39
The following table lists the holding registers for the “C” Group Intelligent Input
Functions.
I
“C” Group Intelligent Terminal Functions
Func.
Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.
C001
Terminal [1] function
R/W
See
1103h
04355 0, 1, 2, 3,
4, 5, 6, 7,
8, 9, 11,
12, 13,
15, 16,
18, 19,
20, 21,
22, 23,
24, 27,
28, 29,
31, 50,
51, 255
—
C002
Terminal [2] function
R/W
1104h
04356
C003
Terminal [3] function
R/W
1105h
04357
C004
Terminal [4] function
R/W
1106h
04358
C005
Terminal [5] function
R/W
1107h
04359
C011
Terminal [1] active state R/W Select logic convention, two
option codes:
00... normally open [NO]
01... normally closed [NC]
110Bh 04363
0, 1
—
C012
Terminal [2] active state R/W
110Ch 04364
0, 1
—
C013
Terminal [3] active state R/W
110Dh 04365
0, 1
—
C014
Terminal [4] active state R/W
110Eh
04366
0, 1
—
C015
Terminal [5] active state R/W
110Fh
04367
0, 1
—
C021
Terminal [11] function
R/W
1114h
04372
0, 1, 2, 3,
4, 5, 6, 7,
8, 9
—
C022
Terminal [12] function
R/W
1115h
04373
C026
Alarm relay terminal
function
R/W
1119h
04377
C028
[AM] signal selection
R/W Two available functions:
00... Actual motor speed
01... Motor current
111Bh 04379
0, 1
—
C031
Terminal [11] active
state
R/W Select logic convention, two
option codes:
00... normally open (NO)
01... normally closed (NC)
111Dh 04381
0, 1
—
C032
Terminal [12] active
state
R/W Select logic convention, two
option codes:
00... normally open (NO)
01... normally closed (NC)
111Eh
04382
0, 1
—
C036
Alarm relay active state
R/W Select logic convention, two
option codes:
00... normally open (NO)
01... normally closed (NC)
1122h
04370
0, 1
—
Summary of Contents for L200-002NFE2
Page 2: ......
Page 46: ......
Page 80: ......
Page 204: ......
Page 212: ......
Page 229: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 280: ......
Page 297: ...L2002 Inverter Appendix D D 5 L1 L2 L3 PE L2002 inverter with book type filter M 3 ...