L200
2
Inverter
Appendix B
B–25
The table below lists the holding registers for the “F” Group Main Profile Parameters.
Note 1:
When the value is 10000 (100.0 seconds), a value in the second decimal place
is ignored.
Holding Registers, “F” Group Main Profile Parameters
Func.
Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.
F002
(high)
Acceleration (1) time
setting *1
R/W Standard default acceleration,
range is 0.01 to 3000 sec.
1014h
04116
1 to
300000
0.01
sec
F002
(low)
R/W
1015h
04117
F202
(high)
Acceleration (1) time
setting, 2nd motor *1
R/W Standard default acceleration,
2nd motor,
range is 0.01 to 3000 sec.
1501h
05377
1 to
300000
0.01
sec
F202
(low)
R/W
1502h
05378
F003
(high)
Deceleration (1) time
setting *1
R/W Standard default deceleration,
range is
0.01 to 3000 sec.
1016h
04118
1 to
300000
0.01
sec
F003
(low)
R/W
1017h
04119
F203
(high)
Deceleration (1) time
setting, 2nd motor *1
R/W Standard default deceleration,
2nd motor,
range is 0.01 to 3000 sec.
1503h
05379
1 to
300000
0.01
sec
F203
(low)
R/W
1504h
05380
F004
Keypad Run key routing R/W Two options; select codes:
00 ...Forward
01 ...Reverse
1018h
04120
0, 1
—