6-40
Troubleshooting
HVM Navigator User's Guide - Migration
Detailed error information detected by LPAR Mover module
Format
“EMG” op1 : don’t_care : don’t_care : (op3) : ”LPAR Mover” : message
•
“EMG”: Fixed characters meaning error message.
•
“LPAR Mover”: Fixed characters meaning LPAR Mover module that executes
migration on HVM side.
•
don’t_care: Values at this position are negligible.
•
op1: 1st operand that identifies error detail in hexadecimal code. See
Description.
•
op3: 3rd operand that identifies reason in hexadecimal code. See
Description.
•
Message: Error detail in text. See Description.
Table 6-4 Error message detected by LPAR Mover
op1
op3
Message [interpretation]
Suggested action
0x00 00000000 0030 04
0x00 00000000 0040 04
0x20 Terminated by user.
None.
0x00 00000000 0030 04
0x33 LPAR Migration was canceled. USB is
attached to the specified LPAR.
Detach the USB device and retry.
0x00 00000000 0030 05 to 0x00
00000000 0070 05
0x20 Terminated by user.
None.
0x00 ******** 0030 04 to 0x00
******** 0070 04
0x02 Connection refused (LPAR Mover-LPAR
Mover)
[Migration terminated by a network
failure.]
Check for recovery of connection
between the source HVM and the
destination HVM, and then retry
migration.
0x00 ******** 0030 05 to 0x00
******** 0070 05
0x02 Connection refused (LPAR Mover-LPAR
Mover)
[Migration terminated by a network
failure.]
Check for recovery of connection
between the source HVM and the
destination HVM, and then retry
migration.
0x00 00000000 1008 05
0x01 The specified LPAR had been moved,
but The MMS thread could not allocate
enough resource to activate.
[An error occurred when activating the
specified LPAR at the destination.]
Reserve enough amount of free
memory to activate the specified
LPAR at the destination.
0x00 00000000 0030 05
0x31 Init Connection Failed (HVM-HVM).
Connection between the source and
destination HVMs has failed.
Retry the migration after
confirming connection between
the source and destination HVMs.
Summary of Contents for HVM Navigator V03-06
Page 8: ...viii Contents HVM Navigator User s Guide Migration ...
Page 22: ...1 8 Overview HVM Navigator User s Guide Migration ...
Page 96: ...2 74 Usage environments HVM Navigator User s Guide Migration ...
Page 120: ...3 24 Migration procedures HVM Navigator User s Guide Migration ...
Page 134: ...3 38 Migration procedures HVM Navigator User s Guide Migration 10 Click Show Config button ...
Page 161: ...Migration procedures 3 65 HVM Navigator User s Guide Migration 4 Click Close button ...
Page 201: ...Migration procedures 3 105 HVM Navigator User s Guide Migration 3 Click OK button ...
Page 250: ...5 18 Usage notes HVM Navigator User s Guide Migration Figure 5 1 Migration Progress window ...
Page 254: ...5 22 Usage notes HVM Navigator User s Guide Migration Figure 5 3 HVM Console window ...
Page 262: ...5 30 Usage notes HVM Navigator User s Guide Migration ...
Page 306: ...6 44 Troubleshooting HVM Navigator User s Guide Migration ...
Page 310: ...7 4 List of icons HVM Navigator User s Guide Migration ...