6-36
Troubleshooting
HVM Navigator User's Guide - Migration
op1
op2
op3
Message [interpretation]
Suggested action
0x00 1******* 0030 02 0x0000 0000 0004 ffff
0x01 The MMS could not define an
LPAR because there is not
enough memory in the
destination blade.
Reserve enough amount of
free memory in the
destination HVM and then
retry migration.
0x00 1******* 0030 02 0x0000 0000 000A ffff
0x01 The MMS could not define an
LPAR because the name of
the specified LPAR is
'NO_NAME'
Rename the migration
specified LPAR to a unique
name in the system and
then retry migration.
0x00 1******* 0030 02 0x0000 0000 **** ffff
0x01 The MMS could not define an
LPAR because the specified
LPAR has an unexpected
condition.
[Unable to define an LPAR at
the destination to have the
same configuration as the
source.]
Reserve enough amount of
free resource in the
destination and then retry
migration.
0x00 2******* 0030 02 0x0000 0000 0000 0000 0x01 The MMS could not define a
USB port on an LPAR because
the specified USB has an
unexpected condition.
Check source and
destination LPAR
configurations and retry.
0x00 3******* 0030 02 0x 4-byte_VnicID 0001 2-
byte_VnicNum
0x01 There is not enough VNIC
device#3 (Virtual NIC: 2a) to
define an LPAR.
[There is no NIC at the
destination corresponding to
the NIC at the source.]
Inspect the physical
configuration of NIC (LAN
adapter) at the destination,
reconfigure it to meet that
of the source, and then
retry migration.
0x00 3******* 0030 02 0x 4-byte_VnicID 0002 2-
byte_VnicNum
0x01 The MMS could not define a
VNIC#3 (Virtual NIC: 2a) on
an LPAR because the
specified VNIC has VLAN IDs
which are not acceptable in
the destination blade.
[Unable to define an NIC at
the destination to have the
same VLAN configuration
settings as the source.]
Inspect the physical
configuration of NIC (LAN
adapter) at the destination
as well as review the NIC
settings (VLAN mode and
VLAN ID) at the source,
reconfigure them to meet
each other, and then retry
migration.
0x00 5******* 0030 02 0x 4-byte_VnicID 0003 2-
byte_VnicNum
0x01 The MMS could not define a
VNIC#3 (Virtual NIC: 2a) to
a promiscuous mode because
this mode is not acceptable
in the destination blade.
[Unable to define a VNIC at
the destination to have
promiscuous mode in the
same configuration as the
source.]
Inspect the physical
configuration of NIC (LAN
adapter) at the destination
as well as review the NIC
setting (promiscuous mode)
at the source, reconfigure
them to meet each other,
and then retry migration.
0x00 3******* 0030 02 0x 4-byte_VnicID ****
2-byte_VnicNum
0x01 The MMS could not define an
LPAR because the specified
VNIC#3 (Virtual NIC: 2a) has
an unexpected condition.
[Unable to define a VNIC at
the destination to have the
same configuration as the
source.]
Inspect the physical
configuration of NIC (LAN
adapter) at the destination,
reconfigure it to meet that
of the source, and then
retry migration.
Summary of Contents for HVM Navigator V03-06
Page 8: ...viii Contents HVM Navigator User s Guide Migration ...
Page 22: ...1 8 Overview HVM Navigator User s Guide Migration ...
Page 96: ...2 74 Usage environments HVM Navigator User s Guide Migration ...
Page 120: ...3 24 Migration procedures HVM Navigator User s Guide Migration ...
Page 134: ...3 38 Migration procedures HVM Navigator User s Guide Migration 10 Click Show Config button ...
Page 161: ...Migration procedures 3 65 HVM Navigator User s Guide Migration 4 Click Close button ...
Page 201: ...Migration procedures 3 105 HVM Navigator User s Guide Migration 3 Click OK button ...
Page 250: ...5 18 Usage notes HVM Navigator User s Guide Migration Figure 5 1 Migration Progress window ...
Page 254: ...5 22 Usage notes HVM Navigator User s Guide Migration Figure 5 3 HVM Console window ...
Page 262: ...5 30 Usage notes HVM Navigator User s Guide Migration ...
Page 306: ...6 44 Troubleshooting HVM Navigator User s Guide Migration ...
Page 310: ...7 4 List of icons HVM Navigator User s Guide Migration ...