6. RAS FEATURES IN HF-W100E/IoT
6-21
6.3.4 Recording the event log
Table 6-11 shows the data recorded in the Event Log by the CODESYS runtime
environment monitor.
Table 6-11 List of Events Recorded in the Event Log
Event ID
Source
Type
Description
1000
HIoTRAS_APP Information Watchdog timer monitoring has been started.
2000
HIoTRAS_APP Information Timeout occurs for the watchdog timer.
Timeout action is executed.
2001
HIoTRAS_APP Information Timeout action is completed successfully.
1100
HIoTRAS_APP Warning
Initialization of watchdog timer monitoring service
terminates with an error. The service has been started
with default value.
1200
HIoTRAS_APP Error
Initialization of watchdog timer monitoring service
terminates with an error. The service could not been
started.
2100
HIoTRAS_APP Error
Execution of timeout action terminates with an error.
Note: If the action at the time of time-out is either of the following, Event ID 2001 is not recorded.
• Shutting down and restarting the device
• Shutting down and restarting the device (forced)