275
Transmitting: Figure 14.6 shows an example of a flowchart for data transmission. This procedure
should be followed for data transmission after initializing SCI3.
Start
End
Read bit TDRE
in SSR
1
2
3
Write transmit
data to TDR
Read bit TEND
in SSR
Set PDR = 0,
PCR = 1
Clear bit TE to 0
in SCR3
No
TDRE = 1?
Yes
Continue data
transmission?
No
TEND = 1?
No
Yes
Yes
Yes
No
Break output?
Read the serial status register (SSR)
and check that bit TDRE is set to 1,
then write transmit data to the transmit
data register (TDR). When data is
written to TDR, bit TDRE is cleared to 0
automatically.
When continuing data transmission,
be sure to read TDRE = 1 to confirm that
a write can be performed before writing
data to TDR. When data is written to
TDR, bit TDRE is cleared to 0
automatically.
If a break is to be output when data
transmission ends, set the port PCR to 1
and clear the port PDR to 0, then clear bit
TXD in PMR7 and bit TE in SCR3 to 0.
1.
2.
3.
Figure 14.6 Example of Data Transmission Flowchart (Asynchronous Mode)
Summary of Contents for H8/3660
Page 4: ......
Page 26: ...10 ...
Page 82: ...66 ...
Page 152: ...136 ...
Page 154: ...138 ...
Page 260: ...244 ...