EXHAUST SYSTEM (J08E)
EN04–36
(3)
Install the lower side of the lifting clamp.
NOTICE
When installing the lower side of the lifting clamp, do not forget to
place the spacer.
(4)
Install the pipe between the combustion chamber and the differential
pressure sensor.
NOTICE
When installing the differential pressure sensor pipe, wipe off the old
anti-seizure lubricant on the flare nut and apply new anti-seizure lubri-
cant.
Recommended anti-seizure lubricant: NEVER-SEEZ Pure Nickel
Special (Bostic inc.)
Tightening Torque:
25-35 N
m {255-356 kgf
cm, 19-25 lbf
ft} (Flare nut)
(5)
Install the burner burning air hose.
NOTICE
•
When tightening, fix the hexagonal part under the swivel with the
wrench.
•
Before reassembling, remove the combustion air valves (
✩
2
places) without bending the hose so that the valves will be free.
(6)
Connect the burner flame temperature sensor connector.
Spacer
Lifting clamp
(Down side)
SAPH011060400063
Pipe to the differential
pressure sensor
Combustion
chamber
SAPH011060400064
Swivel
Hexagonal part
SAPH011060400065
Connector
Burner flame
temperature sensor
SAPH011060400066