EXHAUST SYSTEM (J08E)
EN04–35
(5)
Dismount the pipe between the combustion chamber and the differen-
tial pressure sensor.
(6)
Remove the lifting clamp.
(7)
Remove the fastening bolt secured to the DPR filter and then the com-
bustion chamber.
(8)
Remove the combustion chamber.
(9)
Remove the fastening bolt secured to the chamber subassembly and
then the DPR filter.
(10) Remove the DPR filter.
2.
INSTALL THE DPR FILTER.
(1)
Install the DPR filter to the chamber subassembly.
NOTICE
•
Before installing check if the DPR filter has the “14” mark on it.
•
Replace with a new gasket.
•
Tighten the fastening bolts in the diagonal order.
(2)
Install the combustion chamber to the DPR filter.
NOTICE
•
Replace with a new gasket.
•
Tighten the fastening bolts in the diagonal order.
Pipe to differential
pressure sensor
Combustion
chamber
SAPH011060400060
SAPH011060400061
"14" mark
SAPH011060400060-1
SAPH011060400062