EXHAUST SYSTEM (J08E)
EN04–49
2.
CONNECT THE HOSE.
(1)
Install the hose to the differential pressure sensor with clamps (4 pcs).
NOTICE
If the differential pressure sensor hose is inserted incorrectly, the
DPR will not operate properly.
! CAUTION
•
Connect the white marks of the sensor and the pipe.
•
Insert the hoses certainly against the sensor body.
•
Insert the hoses certainly against the sensor spool.
3.
INSTALL THE HARNESS.
(1)
Connect the connector to the differential pressure sensor.
Differential
pressure sensor
Clamp
Clamp
Hose
SAPH011060400083
SAPH011060400084
Differential
pressure sensor
Connector
SAPH011060400085