EMISSION CONTROL (J08E)
EN10–27
9.
NOx SENSOR 2
(1)
IMPORTANT POINT - DISMOUNTING
a.
Remove the clips.
b.
Disconnect the harness coupler.
c.
Remove the NOx sensor controller.
d.
Remove the sensor.
NOTICE
After removing the sensor, check that there is no entry of foreign mat-
ters inside the muffler.
(2)
IMPORTANT POINT - MOUNTING
a.
Mount the sensor.
Tightening Torque:
40-60 N
m {407-611 kgf
cm, 29-44 lbf
ft} (Sensor)
Tightening Torque:
3.9-7.1 N
m {40-72 kgf
cm, 2.9-5.2 lbf
ft} (Controller)
b.
Mount the NOx sensor controller.
c.
Connect the harness coupler.
d.
Mount the clips.
NOTICE
When reassembling, apply anti-seizure lubricant to the temperature
sensor.
INSPECTION AND REPAIR
EN0110610H300001
Inspect the SCR-related components in accordance with the table
below and perform a repair or replacement if necessary.
Clip
Sensor
Clip
Harness
coupler
SHTS011061000061
Clip
Sensor
Clip
Harness
coupler
SHTS011061000062
Item
Content
Action
Travel distance
DEF filter element (& equalizing element)
Replacement
Replacement
60,000 mile