Reason of Arming Failure
• Intrusion detector triggered (excepts the detector on the exit route).
• Panic alarm device triggered.
• Tampering alarm occurred.
• Communication exception
• Main power supply exception
• Backup battery exception
• Alarm receiving fault
• Sounder fault
• Low battery of the keyfob
• Others
Arming with Fault
While the arming is stopped with fault, user in level 2 has the permission to arm the system with
fault (forced arming).
Fored arming only taks effect on the current arming operation.
The forced arming operation will be record in the event log.
5.2 Disarming
You can disarm the system with keypad, keyfob, card, client software, or mobile client.
Disarming Indication
The arming/disarming indicator flashes 30s while the user successfully disarm the system through
the entry/exit route.
The system will report the disarming result after the operation completed.
Entry Delay Duration
Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1.
Early Alarm
If either the intrusion or tampering alarm occurs on the enter/exit route when the control panel is
in the status of entry delay, the control panel then enters the early alarm mode.
The early alarm duration can be set (> 30s).
The control panel will reports the alarm only if the alarm event lasts over the duration of early
alarm with the addition of entry delay.
5.3 Use the Keyfob
The keyfod is used for away arming, stay arming, disarming, panic alarm, and clearing alarm.
Hybrid Security Control Panel User Manual