Input Types
Operations
Gas Zone
The zone activates all the time with sound or sounder output
when alarm occurs.
Audible Response: Trigger the system sound and sounder.
Voice Prompt: Zone X gas alarm.
Medical Zone
The zone activates all the time with beep confirmation when
alarm occurs.
Audible Response: Trigger the system sound and sounder.
Voice Prompt: Zone X medical alarm.
Timeout Zone
The zone activates all the time. The zone type is used to monitor
and report the "ACTIVE" status of a zone, but it will only report
and alarm this status after the programmed time has expired (1
to 599) seconds.
Disabled Zone
Alarms will not be activated when the zone is triggered or
tampered.
Audible Response: No system sound (voice prompt or sounder).
Key Zone
The linked area will arm after being triggered, and disarm after
being restored. In the case of the tampering alarm, the arming
and disarming operation will not be triggered.
Virtual Zone (Keypad/Keyfob)
The system will immediately alarm when it detects triggering
event after system armed.
Audible Response: Trigger the system sound and sounder.
Voice Prompt: Buzzer beeps.
Tamper Alarm
The system will immediately alarm when it detects triggering
event after system armed.
Audible Response: Trigger the system sound and sounder.
Voice Prompt: Zone X tampered.
Link
Trigger the linked device when event occurs.
e.g. The output expander linked relays will be enabled when the
control panel is armed.
Arm
When armed: Voice prompt for fault. You can handle the fault
according to the voice prompt.
• System sound for arming with card or keyfob.
• Voice prompt for fault. You can handle the fault according to
the voice prompt.
• Fault event displays on client. You can handle the fault via
client software or mobile client.