Figure 4-3 Secure Door Control Unit Wiring
Note
The secure door control unit should connect to an external power supply separately. The suggested
external power supply is 12V, 0.5A.
4.4 Wire Fire Module
4.4.1 Wiring Diagram of Door Open When Powering Off
Lock Type: Anode Lock, Magnetic Lock, and Electric Bolt (NO)
Security Type: Door Open When Powering Off
Scenario: Installed in Fire Engine Access
Type 1
Note
The fire system controls the power supply of the access control system.
DS-K1T690 Series Face Recognition Terminal User Manual