![HIKVISION DS-K1T690 Series User Manual Download Page 37](http://html1.mh-extra.com/html/hikvision/ds-k1t690-series/ds-k1t690-series_user-manual_2133918037.webp)
Chapter 4 Wiring
The device supports connecting to the RS-485 terminal, the door lock, the exit button, the alarm
output/input devices, the Wiegand card reader, the access controller, and the power supply. You
can wire the peripherals according to the descriptions below.
If connect the Wiegand card reader with the access controller, the face recognition terminal can
transmit the authentication information to the access controller and the access controller can
judge whether to open the door or not.
Note
●
If the cable size is 18 AWG, you should use a 12 V switched-mode power supply. And the
distance between the power supply and the device should be no more than 20 m.
●
If the cable size is 15 AWG, you should use a 12 V switched-mode power supply. And the
distance between the power supply and the device should be no more than 30 m.
●
If the cable size is 12 AWG, you should use a 12 V switched-mode power supply. And the
distance between the power supply and the device should be no more than 40 m.
4.1 Terminal Description
The terminals contains power input, alarm input, alarm output, RS-485, Wiegand output, and door
lock.
The terminal's diagram is as follows:
DS-K1T690 Series Face Recognition Terminal User Manual
23