5-23
5.14 Maintenance of the Circulatory Lubrication System
• Hold the woven lose in the collecting container.
• To pump out the used oil, switch on the main spindle
at a low speed.
• Slip the woven lose [4] on again and tighten
the lose clamp [3].
• Clean the oil filter. See description (below).
• Unscrew and remove the lid [2] of the storage tank
and top up with lubricating oil in accordance with our
recommendations on page 5-7.
Cleaning the Filter
The oil filter must be cleaned every month or after
every 200 operating hours.
Completely unscrew the lid of the filter [5] (17 mm
wrench) and remove the gauze filter.
Screw on the lid of the filter [5] immediately in order
to avoid leakage of the storage tank.
Clean the filter by blowing though it or by washing it
in a solvent. Replace if the fabric of the filter is
damaged.
• The heat valve [6] has been set to 18° in the factory
and must not be changed.
• The maximum ambient temperature is +32°. If the
machine is located in small halls or in halls with a
high drop of heat and humidity provide sufficient
ventilation. If necessary, install an exhaust fan.
• The capacitor [7] must be carefully cleaned every
month by means of compressed air.
1
2
4
3
5
6
7
Summary of Contents for UWF 902 H
Page 1: ...Universal Toolroom Milling and Boring Machine Operating Manual UWF 902 H ...
Page 2: ...1 2 3 4 5 12 13 15 14 9 10 11 8 7 16 6 17 ...
Page 4: ...Control TNC 426 ...
Page 30: ...2 11 2 2 7 Preparation for Initial Start Up 4 1 ...
Page 64: ...4 2 4 1 2 Technical Data Tool Changer Tool changing horizontal Tool changing vertical ...
Page 74: ...4 12 0 450 180 18 468 30 85 10 465 47 63 14 H7 ca 245 ca 470 ca 75 208 0 500 73 92 4 2 2 ...
Page 91: ...4 29 4 4 5 1 Cover plate 2 Recess 3 Taper pin 4 Hand crank ...