9 .3 .3 Synchronising time and date
f
Click on
Synchronise with PC time
5
.
;
Clock time and date of the power pack are synchronised
with the PC connected to the device.
Time and date are saved in the power pack and have to be
rechecked if the power pack is subsequently replaced.
9 .3 .4 Displaying binding information
Binding information
7
shows the process data of the
last binding performed with the connected CPK hybrid.
9 .3 .5 Selecting a parameter set
In the parameter sets, preset values are grouped and
transferred to the CPK hybrid,
f
Select a configured parameter set in the
Parameter set
8
field.
;
The changed parameters are transferred to the CPK
hybrid.
9 .3 .6 Setting interruption front sensor
The
Interruption, front sensor
setting
9
enables you to
decide how long the level sensor can remain busy
without the
Error, front cap
message appearing on the
display,
f
Select the level in the
Interruption, front sensor
9
field.
;
There are five levels:
• Level 1: 0.0 seconds
• Level 2: 0.3 seconds
• Level 3: 0.5 seconds
• Level 4: 0.7 seconds
• Level 5: 0.9 seconds
;
The setting is changed and transferred to the CPK hybrid.
9 .3 .7 Setting the binding check
The
Check of binding
setting
10
enables you to decide
whether or not the
Error, binding force
message
appears on the display,
f
Set the binding in the
Check of binding
10
field,
"Check of binding" on page 17.
The following
options are available:
• OFF
• Error notification
• Acknowledgement
;
The setting is changed and transferred to the CPK hybrid.
9 .3 .8 Activating consecutive trigger
Consecutive trigger
11
effects continuous binding
without repeatedly actuating the start trigger. Bindings
will be carried out as long as the start trigger remains
pressed.
f
Activate the
continuous drive
11
.
9 .3 .9 Activating links
• Function
&1
concerns the link between the foot pedal
and the regular start trigger on the handle. When this
function is selected, binding only takes place if there is a
simultaneous start trigger (signal) from the foot pedal
and from the handle. If one of the two signals does not
occur, no binding takes place (even if the handle is
triggered).
• Function
&2
concerns the link between the Last-Tie
sensor (Phoenix socket on the power pack) and the
regular start trigger on the handle. When this function is
selected, binding only takes place if a signal is sent from
the Last-Tie sensor and the handle simultaneously. If one
of the two signals does not occur, no binding takes place
(even if the handle is triggered).
f
Activate the desired link.
9 .3 .10 Status indicators
The
Tool status
12
field displays the operating status of
the CPK hybrid.
Colour
Status
Connection to the
power pack CPK
Green
Connection active
Red
Error message active
Grey
No connection / connection
interrupted
Connection to
CPK hybrid
Green
Connection active
Red
Error message active
Grey
No connection / connection
interrupted
Status of
CPK hybrid
Green
Ready
Yellow
Busy
Blue
Main menu on CPK hybrid active
Binding not possible
Red
Error message active
Grey
No connection / connection
interrupted