Operating Instructions • CPK hybrid • 11-2021 • v04 • 106-29004
Operation
13
6
Operation
6 .1 Switching on and off in mains operation
6 .1 .1 Switching on
f
The power-supply outlet must be readily accessible
so that the power pack and the CPK hybrid can be
de-energised if the need arises.
f
Keep the main switch OFF when the CPK hybrid is not
in use or being replaced.
f
Switch the power pack ON at the main switch.
;
The
Signal
and
Power
LEDs on the power pack
illuminate in green.
;
The LED status display on the CPK hybrid lights up green.
;
The start menu appears on the display,
.
;
The CPK hybrid is ready for use.
6 .1 .2 Switching off
f
Switch the power pack OFF at the main switch.
6 .2 Switching on and off in battery operation
6 .2 .1 Switching on
f
With the battery pack connected, press the battery pack
on/off button on the handle for approx. 2 seconds.
;
If the CPK hybrid is not operated for more than
10 minutes, it switches to standby mode.
f
To restore operational readiness, press the start trigger
once.
6 .2 .2 Switching off
f
Press the battery pack on/off button on the handle.
;
The battery pack switches to standby mode.
6 .3 Loading cable ties
1
2
3
f
Insert cable tie bandoleer
1
parallel with the drum.
;
Make sure that the cable-tie heads
2
are facing up.
f
Press the trigger
3
.
f
If there are no cable ties in the device three blank shots
are fired.
;
The cable ties are loaded.
6 .4 Positioning and binding items for bundling
f
Select the
Force level
and/or
Quality
parameters,
"Accessing the parameter set" on page 14 or
"Selecting a parameter set" on page 21.
The device is suitable for the following bundle
geometries:
42 mm
20 mm
1
2
3
The distance from front cap
1
to flat
2
must be at least
42 mm. Bundle
3
can be no more than 20 mm in
diameter.
CAUTION
Crush hazard when jaws close .
f
Do not insert fingers between upper and lower jaws and
do not keep your finger on the trigger.
f
Always keep the power pack switched OFF when
clearing a blockage.
1
3
2
f
Centre the bundle
1
in line with front-cap screws
3
.
Space adjacent cable ties at least 10 mm apart.
f
Press the trigger
2
.
;
The bundle
1
is secured by the cable tie.