Operating Instructions • CPK hybrid • 11-2021 • v04 • 106-29004
Troubleshooting
32
10 .2 Performing a reset
A reset of the CPK hybrid always has to be performed
before repair work is undertaken.
1
2
3
4
f
Switch on the CPK hybrid.
f
Push the actuator for bandoleer cutter
2
to the left.
f
Press the catch
3
.
f
Open the gate
1
.
f
Remove cable-tie residues where necessary.
f
Press the reset button
4
.
f
Close the gate
1
.
10 .3 Display messages
DISPLAY MESSAGE
POSSIBLE CAUSE
SOLUTION
Remove cable-tie residues
Error, front cap
• There are residues of cable
ties trapped behind the front
cap.
• The level sensor is busy.
f
Clean the front sensor.
f
If applicable, carefully remove the cable-tie residues.
Close gate
Error, gate
• Drum is not in the correct
position.
• The gate is open.
f
Open the gate and turn the drum to the correct
position.
f
Close the gate.