Operating Instructions • CPK hybrid • 11-2021 • v04 • 106-29004
Troubleshooting
31
f
Activate the option
Long waiting time
as well.
;
The holding time before cutting increases. This gives the
binding more time to release tension.
If only the
Cut with the tension released
option is
activated, the hold time is 100 ms, whereas the additional
option
Long waiting time
increases the hold time to
200 ms.
f
Activate the
Display on tool
option.
;
The name of the parameter set is displayed on the tool.
f
In mode
2
Loop
, use the
Diameter
4
slider to set the
diameter of the bundle.
;
The set diameter is shown on the display of the CPK
hybrid.
f
In cutting mode
3
Cut with projecting cabletie end
,
use the projecting cable-tie end slider to set the length of
the projecting cable ties.
;
The set projecting cable-tie end is shown on the display
of the CPK hybrid.
f
For cut-free binding, select the cutting mode
3
No
cutting
.
f
Click on
Accept
6
to save the settings.
;
The overview of the parameter sets is displayed,
"Parameter set menu" on page 29
f
Synchronise the settings with the CPK hybrid,
"Synchronising parameter sets" on page 29.
9 .9 Exporting process data from the power pack
NOTE
The power pack must be restarted before the transmission, as
otherwise the CSV file will be written incorrectly and it will
not be possible to convert it.
Bindings cannot be triggered while a data transfer is in
progress.
Data
Signal
Power
Pow
er p
ack C
PK
2
1
f
Switch the power pack off and on again.
f
Disconnect the power pack from the PC.
f
Plug a USB memory stick
2
into the power pack.
The USB memory stack must be FAT32-formatted.
;
The
Data
LED
1
lights up green as soon as the device
recognises the USB memory stick.
;
The data are exported to the USB memory stick.
;
The display shows the message that the CPK hybrid
should not be switched off.
USB active
Do not switch off
;
During the saving process, the
Data
LED
1
will light up
red/blue.
;
As soon as the data transfer is complete, the
Data
LED
1
lights up green.
f
Unplug the USB memory stick
2
.
;
The
Data
LED
1
goes out and the CPK hybrid is ready
for use.
f
Switch the power pack off and on again.
f
Connect the power pack to the PC.
10 Troubleshooting
10 .1 Important notes
CAUTION
Crush hazard when jaws close .
f
Do not insert fingers between upper and lower jaws and
do not keep your finger on the trigger.
f
Always keep the power pack switched OFF when
clearing a blockage.
CAUTION
Crush hazard due to moving/rotating parts when
service flaps are open .
f
Do not insert fingers underneath the drum and do not
keep your finger on the trigger.
f
Always keep the power pack switched OFF when
clearing a blockage.