Operating Instructions • CPK hybrid • 11-2021 • v04 • 106-29004
Technical data
42
12 .2 Power pack CPK
110
258
93
3,3
Value
Line voltage
100 V – 230 V
Line frequency
50/60 Hz
Protection class
I
Size L × W × H
approx. 260 mm × 110 mm × 93 mm
Weight
approx. 1300 g
Back-up battery
CR 2032 3V or equivalent
12 .3 Battery pack
Value
Voltage range
18 V
Battery pack capacity
2 Ah
Charging current
3 A
Charging time
40 min.
12 .4 Charger
The chargers are only suitable for charging Metabo and
CAS (Cordless Alliance System) battery packs.
Value
Voltage range
12 – 36 V
Battery pack capacity
2 – 8 Ah
Charging current
1.5 – 4 A
Charging time
30 – 250 min.
12 .5 Noise and vibration information
Emission sound pressure level L
pA
Uncertainty K
pA
65 dB re20 μPa
3 dB
Sound power level L
WA
Uncertainty K
WA
76 dB re1pW
3 dB
Aggregate figure for vibration a
h
Uncertainty K
0.8 m/s
2
1.5 m/s
2
The vibration level as stated here is a measured value
obtained by the standardised method set out in
EN 60745-1:2009; it can be used for the purposes of device
comparison.
The figure for vibration stated here is for the power tool
in conditions of its intended use and can differ from the
actual figure for the power tool in conditions of other
use or if not adequately serviced.
Accurately estimating vibration load over a certain work
period entails making due allowance for the times
during which the device is switched off or running, but
not actually in use. This can reduce vibration load over
the entire work period by a significant margin.
f
Implement additional safety measures to protect the
operator from the effects of vibration, for example:
• Servicing of power tools and use tools
• Keeping hands warm
• Workflow organisation