Operating Instructions • CPK hybrid • 11-2021 • v04 • 106-29004
Troubleshooting
35
DISPLAY MESSAGE
POSSIBLE CAUSE
SOLUTION
1. Check battery in power pack
2. Press Reset button
Time loss
• The back-up battery for the
clock in the power pack has
discharged.
f
Change the back-up battery,
of the power pack" on page 36.
f
Press the Reset button.
10 .4 Possible fault
FAULT PATTERN
POSSIBLE CAUSE
SOLUTION
Loops form
• Bundle diameter is
unsuitable.
f
Use a suitable bundle diameter,
binding items for bundling" on page 13.
• Tie advancer is not in the
correct position.
f
Check the position of the tie advancer,
• Spring in upper jaw is faulty.
f
Check upper jaw flap in upper jaw with spring,
"Replacing upper jaw" on page 37.
• Lower jaw is blocked.
f
Check lower jaw,
"Checking front cap and position
f
Remove blockage.
Binding not possible.
Cable tie shoots straight
out.
• Upper jaw is blocked.
f
Check upper jaw,
f
Remove blockage.
Cable tie is not cut off
flush.
• Cutter in front cap is not in
correct position.
f
Check position of cutter in front cap and remove
cable-tie residues,
"Checking front cap and position
10 .4 .1 Troubleshooting a cable-tie bandoleer malfunction
Be sure to check the information on the display,
f
Switch the power pack OFF.
1
2
3
f
Push the actuator for bandoleer cutter
2
to the left.
f
Press the catch
3
.
f
Open the gate
1
.
4
f
Press the actuator for service flap left
4
.
f
Open the left service flap.
f
Open the right service flap.