Settings in the display menu
14
6 .4 .1 Emptying the waste box
The waste box has to be emptied after a maximum
of 120 bindings at a bundle diameter of 3 mm. As
the bundle diameter increases, so does the number
of bindings until the waste box has to be emptied.
1
f
Pull waste box
1
in the direction indicated by the arrow
and empty the box.
f
Close the waste box
1
.
7
Settings in the display menu
After switching on the CPK hybrid, the start screen
appears on the display.
The additional device functions (e.g. clock time) are
configured on the main menu,
AT 2000 CPK
001
1
3
2
1 Enter button to confirm a selection in the navigation menu and increment switch
for display menu settings
2 Select and reset button for CPK hybrid settings in the display menu
3 LED status indicator
Signal
:
Green: CPK hybrid connected and ready
Red: Error
If the optional battery pack is connected, the charge
status indicator is displayed. The functions for setting
the bindings with the CPK hybrid can be accessed and
configured in the display menu.
These include:
• Parameter set
• Force level
• Binding quality
• Loop diameter
• Cutting mode
• Cut with the tension released
• Standby mode
f
Use the Select button
2
to select the desired setting in
the display menu.
f
Press the Enter button
1
.
f
Press the Enter button
1
several times to return to the
start screen.
f
Check the LED status indicator
3
A printed short guide is included with the CPK hybrid which
schematically explains how to configure the functions.
7 .1 Accessing the settings
7 .1 .1 Accessing the settings by entering the access
code
0 0 0
Access code
Settings
1
2
f
Press the Select button
2
.
;
The access code settings are displayed,
;
Access to the
Settings
menu is protected by a three-digit
access code that can be changed in the HT Data
Management software,
for the CPK hybrid" on page 23
.
The default access code is 000.
When configuring settings in the display menu, the start
screen will be displayed after 10 seconds of inactivity.
7 .1 .2 Accessing the settings without entering the
access code
7 .2 Accessing the parameter set
The preset parameter sets can be accessed or transferred
to the CPK hybrid when the HTDM is connected. The
parameter sets comprise settings which are gathered
into groups. They are managed in the HTDM,
"Parameter set menu" on page 19.
Changing the parameter sets without entering an
access code
f
Press the Enter key
1
and the Select key
2
simultaneously and confirm the access code.
;
Two red arrows are shown on the display in place of the
navigation options.
;
Use the Enter key
1
(arrow pointing up) and the Select
key
2
(arrow pointing down) to switch between the
parameter sets.