4–58
TNC 370 D
Machine Parameters
July 02
Machine
parameter
Function and input
Change via
Reaction
MP1150
Delay time for erasing the nominal velocity
value after an erasable error message
Positioning error <Axis> #
Input:
0.000 to 65.535 [s]
Recommended: 0
PLC
RUN
MP1220 Automatic
cyclic offset adjustment
Input:
0 to 65 536 [s]
0 = no automatic adjustment
PLC
RUN
MP1320
Direction for traversing the reference marks
Input: %xxxx
Bit
0 to 3
0 = not active
Axis
X to 4
1 = active
Reset
MP1330.0-3
Velocity when traversing the reference
marks
Input:
80 to 300 000 [mm/min]
PLC
RUN
MP1331.0-3
Velocity when leaving the reference end
position (only with MP1350=2)
Input:
80 to 500 [mm/min]
PLC
RUN
MP1340.0-3
Axis sequence when traversing the
reference marks
Input:
0 = No evaluation of the reference mark
1 = Axis X
2 = Axis Y
3 = Axis Z
4 = Axis 4
Reset
MP1350.0-3
Functional sequence when traversing the
reference marks
Input:
0 = linear encoder with distance-coded
reference marks (old routine)
1 = linear encoder with one reference mark
2 = special run (linear measurement via
ROD)
3 = linear encoder with distance-coded
reference marks (new routine)
Reset
Summary of Contents for TNC 370 D
Page 1: ... z ad snnn Technical Information NC Software 286 02x xx ...
Page 44: ...3 9 Mounting Dimensions LE 370 D July 02 Mounting and Electrical Installation TNC 370 D 3 41 ...
Page 48: ...July 02 Mounting and Electrical Installation TNC 370 D 3 45 3 11 Grounding plan ...
Page 49: ...3 46 TNC 370 D Mounting and Electrical Installation July 02 ...