4–60
TNC 370 D
Machine Parameters
July 02
4.6 Operation with Servo Lag
Machine
parameter
Function and input
Change via
Reaction
MP1710.0-3
Position monitoring for control with servo
lag (erasable)
Input:
0.000 to 1 000.000 [mm]
Recommended: 1.2
·
servo lag
PLC
MP1720.0-3
Position monitoring for control with servo
lag (EMERGENCY STOP)
Input:
0.000 to 1 000.000 [mm]
Recommended: 1.4
·
servo lag
PLC
MP1810.0-3
k
v
factor for control with servo lag
Input:
0.100 to 10.000 [
Fehler
]
!
PLC
MP1820.0-3
Multiplication factor for the kv factor
Input:
0.001 to 1.000
PLC
MP1830.0-3 Characteristic
kink
Input:
0.000 to 100.000 [%]
PLC
4.7 Main Spindle
Machine
parameter
Function and input
Change via
Reaction
MP3010
Output of rotational speed, gear range
Input:
0 = no output of spindle speed
1 = coded output of spindle speed, only if
the speed changes
2 = coded output of spindle speed on each
TOOL CALL
3 = analog output of spindle speed, but
gear change signal only if the speed
changes
4 = analog output of spindle speed, but
gear change signal on each TOOL
CALL
5 = analog output of spindle speed, but no
gear change signal
6 = same as input value 3 but with
controlled spindle for orientation
7 = same as input value 4 but with
controlled spindle for orientation
8 = same as input value 5 but with
controlled spindle for orientation
Reset
MP3020
Speed range for S code output
Input:
0 to 99 999
(with analog output of the spindle speed,
enter 1991 here)
PLC
Summary of Contents for TNC 370 D
Page 1: ... z ad snnn Technical Information NC Software 286 02x xx ...
Page 44: ...3 9 Mounting Dimensions LE 370 D July 02 Mounting and Electrical Installation TNC 370 D 3 41 ...
Page 48: ...July 02 Mounting and Electrical Installation TNC 370 D 3 45 3 11 Grounding plan ...
Page 49: ...3 46 TNC 370 D Mounting and Electrical Installation July 02 ...