4–62
TNC 370 D
Machine Parameters
July 02
Machine
parameter
Function and input
Change via
MP3240.1
Minimum nominal value voltage
Input:
0 to 9.999 [V]
MP3240.2
Jog voltage for gear changing
(M4009/M4010)
Input:
0 to 9.999 [V]
MP3310
MP3310.0
MP3310.1
Limits for spindle override
Input:
0 to 150 [%]
Upper limit
Lower limit
MP3411
MP3411.0-7
Ramp gradient of the spindle at M03 and
M04
Input:
0.000 to 1.999 [V/ms]
Gear range: 1 to 8
PLC
RUN
MP3412
MP3412.0
MP3412.1
MP3410.2
MP3410.3
Multiplier for MP3411.x
Input: 0.000 to 1.999
For M05
For spindle orientation
For tapping
For rigid tapping
PLC
RUN
MP3415
MP3415.0
MP3415.1
MP3415.2
MP3415.3
Transient response of the spindle
(functions like MP1520)
Input:
0 to 1000 [ms]
for M03, M04 and M05
for spindle orientation
for tapping
for rigid tapping
PLC
RUN
MP3420
Positioning window for the spindle
Input:
0 to 360.000 [°]
PLC
RUN
MP3430
Deviation of the reference mark from the
desired position (spindle preset)
Input:
0 to 360.000 [°]
PLC
RUN
Summary of Contents for TNC 370 D