3.7.15 Handwheel Input
Any of the following handwheels can be used with the LE 370 D:
One HR 410 portable handwheel
One HR 130 panel-mounted handwheel or
One HRA 110 handwheel adapter for connecting three HR 150 panel-mounted handwheels
X23 Handwheel Input
D-sub terminal
(female) 9-pin
Assignment
2 0
V
4 +12
V
±
0.6 V (Uv)
6 DTR
7 TxD
8 RxD
9 DSR
1, 3, 5
Not used
Housing External
shield
The interface complies with the recommendations in IEC 742 EN 50 178 for separation
from line power.
3–32
TNC 370 D
Mounting and Electrical Installation
July 02
Summary of Contents for TNC 370 D
Page 1: ... z ad snnn Technical Information NC Software 286 02x xx ...
Page 44: ...3 9 Mounting Dimensions LE 370 D July 02 Mounting and Electrical Installation TNC 370 D 3 41 ...
Page 48: ...July 02 Mounting and Electrical Installation TNC 370 D 3 45 3 11 Grounding plan ...
Page 49: ...3 46 TNC 370 D Mounting and Electrical Installation July 02 ...