July 02
Mounting and Electrical Installation
TNC 370 D
3–37
3.7.16 Analog Inputs
The logic unit and the PL 410 B input/output board can be supplied with analog inputs (
±
10 V) and
inputs for connecting Pt 100 thermistors .
Analog inputs (
±
10 V)
Inputs for Pt 100
thermistors
LE 370 D
3 on connector X48
2 on connector X48
PL 410 B (Id. Nr. 263 217 02)
4
4
The current values of these inputs are interrogated with Module 9003.
Analog inputs:
Voltage
range
-
10 V to +10 V
Input resistance
> 250 k
W
Resolution
100
mV
Internal value range
–100 to +100
Inputs for Pt 100 thermistors:
Constant current
5 mA
Temperature range
0° C to 100° C
Resolution
0.5°
C
Internal value range
0 to 200