5
QUICK START GUIDE
INTRODUCTION
The
HI 904
Karl Fischer Coulometric titrator is extremely flexible, capable of performing a
wide variety of highly accurate and precise water content titration methods.
The
HI 904
finds a titration endpoint using a polarized electrode and an advanced detection
algorithm. A constant flow of current is maintained between the two platinum pins of the
titrator’s electrode. When the solution in the titration vessel contains water, a relatively
large voltage is required to maintain the flow of current between the pins. As the titration
proceeds, the water in the sample is consumed by the iodine that is generated electrolytically
within the vessel. At the end point, all of the water has been reacted and the cell contains
excess iodine. The presence of excess iodine within the titration cell results in a reduction
in the amount of voltage required to maintain the constant current between the pins of the
electrode. The endpoint detection algorithm incorporated in the
HI 904
analyzes both the
electrode response to individual additions of iodine and the shape of the entire titration
curve in order to determine the endpoint of the titration.
Titration reports and methods can be transferred to a PC via a USB interface, saved to a USB
flash drive or printed directly from the titrator. An external monitor and keyboard can be
attached for added convenience.
How can I find certain information?
1. This
Quick Start Guide
will help the user learn how to operate the titrator within
a short period of time. The first analysis will be performed with the aid of the
factory stored methods.
2. The
Instruction Manual
provides a complete description of the operating principles
(user interface, general options, methods, titration mode, maintenance, etc.).
3. The contextual
Help
screens contain detailed explanations about what kind of data
can be set or viewed in every displayed screen.
4. The
Titration Theory
booklet outlines the basic concepts of titration.
Summary of Contents for HI 904
Page 1: ...1 QUICK START GUIDE HI 904 KARL FISCHER COULOMETRIC TITRATOR Revision 1 0 www hannainst com...
Page 4: ...4 QUICK START GUIDE...
Page 7: ...7 QUICK START GUIDE TITRATOR CONNECTIONS Front View Rear View...
Page 17: ...1 INSTRUCTION MANUAL HI 904 KARL FISCHER COULOMETRIC TITRATOR Revision 1 00 www hannainst com...
Page 20: ...4...
Page 22: ...1 2 INTRODUCTION...
Page 24: ...2 2 SETUP...
Page 27: ...2 5 SETUP 2 3 Installation 2 3 1 Titrator Top View...
Page 28: ...2 6 SETUP 2 3 2 Titrator Rear View 2 3 3 Titrator Left side View...
Page 38: ...3 2 USER INTERFACE...
Page 46: ...3 10 USER INTERFACE...
Page 48: ...4 2 GENERAL OPTIONS...
Page 82: ...5 24 METHODS...
Page 84: ...6 2 TITRATION...
Page 94: ...6 12 TITRATION...
Page 96: ...7 2 AUXILIARY FUNCTIONS...
Page 104: ...8 2 MAINTENANCE PERIPHERALS...
Page 112: ...8 10 MAINTENANCE PERIPHERALS...
Page 124: ...9 12 METHODS OPTIMIZATION...
Page 125: ...A3 2 APPENDIX 3...
Page 126: ...A3 6 APPENDIX 3 MAN HI904 09 13...
Page 127: ...A1 1 APPENDIX 1 Appendix 1 Contents A1 TECHNICAL SPECIFICATIONS A1 3...
Page 128: ...A1 2 APPENDIX 1...
Page 132: ...A2 2 APPENDIX 2...
Page 134: ...A2 4 APPENDIX 2...
Page 135: ...A3 1 APPENDIX 3 Appendix 3 Accessories A3 TITRATOR COMPONENTS A3 3...
Page 136: ...A3 2 APPENDIX 3...
Page 140: ...A3 6 APPENDIX 3 MAN HI904 09 13...
Page 141: ...1 GENERAL APPLICATIONS BROCHURE HI 904 KARL FISCHER COULOMETRIC TITRATOR www hannainst com...
Page 142: ......
Page 144: ......
Page 146: ......
Page 150: ...2 TITRATION THEORY...
Page 166: ...18 TITRATION THEORY A B Figure 8 Potential glass electrode mV C...