SmartFOAM
❑
All electrical systems have the potential to
cause sparks during service. Take care to
eliminate explosive or hazardous environments
during service and/or repair.
❑
To prevent electrical shock always disconnect the
primary power source before attempting to service
any part of the Hale Foam system.
❑
To prevent system damage or electrical shock
the main power supply wire is the last
connection made to the Hale Foam motor
controller.
❑
Release all pressure then drain all concentrate and
water from the system before servicing any of its
component parts.
❑
Do not operate system at pressures higher than the
maximum rated pressure.
❑
Use only pipe, hose, and fittings from the foam
pump outlet to the injector fitting, which are rated at
or above the maximum pressure rating at which the
water pump system operates.
❑
Hale Foam proportioning systems are designed for
use on negative ground direct current electrical
systems only.
❑
Do not mount radio transmitter or transmitter
cables in direct or close contact with the
SmartFOAM control unit.
❑
Before connecting the cord sets and wiring
harnesses, inspect the seal washer in the female
connector. If the seal washer is missing or damaged,
water can enter the connector causing corrosion of
the pins and terminals. This could result in possible
system failure.
❑
Always disconnect the power cable, ground
straps, electrical wires and control cables from
the control unit or other Hale Foam system
equipment before electric arc welding at any point
on the apparatus Failure to do so could result in a
power surge through the unit that could cause
irreparable damage.
❑
DO NOT connect the main power lead to small leads
that are supplying some other device, such as a light
bar or siren.
❑
When operating the Hale SmartFOAM in Simulated
Flow mode, an outlet for the foam concentrate must
be provided to prevent excessive pressure build up
in the discharge piping or hoses.
❑
Make sure the foam tank and foam concentrate
suction hoses are clean before making final
connection to foam pump. If necessary, flush tank
and hoses prior to making connection.
❑
Check all hoses for weak or worn conditions after
each use. Ensure that all connections and fittings
are tight and secure.
❑
Ensure that the electrical source of power for the
unit is a negative (
–) ground DC system, of
correct input voltage, with a reserve minimum
current available to drive the system.
❑
The in-line strainer/valve assembly is a low
pressure device and WILL NOT withstand
flushing water pressure in excess of 45 PSI (3
BAR).
❑
When determining the location of Hale Foam
system components keep in mind piping runs,
cable routing and other interferences that could
hinder or interfere with proper system
performance.
❑
Always position the check valve/injector fitting at
a horizontal or higher angle to allow water to
drain away from the fitting. This avoids the
possibility of sediment deposits or the formation
of an ice plug.
❑
The cord sets provided with each Hale Foam
system are indexed to ensure correct receptacle
installation (they insert one way only). When
making cord set connections DO NOT force
mismatched connections as damage can result in
improper system operation.
❑
Make sure all connections are sound, and that
each connection is correct.
❑
The cables shipped with each Hale Foam system
are 100% tested at the factory with that unit.
Improper handling and forcing connections can
damage these cables which could result in other
system damage.
❑
There are no user serviceable parts inside Hale
Foam system electrical/electronic components.
Opening of the motor controller or controller unit
voids the warranty.
❑
Use mounting hardware that is compatible with all
foam concentrates to be used in the system. Use
washers, lock washers and cap screws made of
brass or 300 series stainless steel.
❑
When making wire splice connections, make sure
they are properly insulated and sealed using an
adhesive filled heat shrink tubing.
❑
ALWAYS connect the primary positive power lead
from the terminal block to the master switch
terminal or the positive battery terminal.
❑
Use a minimum 8 AWG type SGX (SAE J1127)
chemical resistant battery cable and protect with
wire loom.
Summary of Contents for SmartFOAM 1.7AHP
Page 3: ...Page 2 SmartFOAM NOTES...
Page 14: ...Page 13 SmartFOAM Figure 2 3 3 and 5 0 Foam Pump Installation Envelope Dimensions...
Page 15: ...Page 14 SmartFOAM SYSTEM DIAGRAM Figure 3 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Page 16: ...Page 15 SmartFOAM Figure 4 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Page 17: ...Page 16 SmartFOAM Figure 5 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Page 18: ...Page 17 SmartFOAM Figure 6 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Page 19: ...Page 18 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainer...
Page 20: ...Page 19 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Page 21: ...Page 20 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandIn lineStrainer...
Page 22: ...Page 21 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandFSSeriesStrainer...
Page 40: ...Page 39 SmartFOAM Figure 18 Typical 4 Inch Check Valve Installation Midship Pump...
Page 51: ...Page 50 SmartFOAM Figure 33 ADT Option Air Hose Connections Part 2...
Page 68: ...Page 67 SmartFOAM NOTES...
Page 80: ...79 Page 79 SmartFOAM NOTES...