Page
26
SmartFOAM
LOW TANK SENSOR OPTIONS
FLOW SENSOR OPTIONS
Each Hale foam system requires a flow sensor for operation. Pipe size must be selected based on the minimum and
maximum water flow in the foam capable discharge. Following is a list of pipe size and rated flow ranges, along with flow
sensor saddle clamp part number. In all instances, a weld fitting may be substituted for the saddle clamp.
Table 4
: Pipe Size versus Flow Range
Pipe Size vs. Flow Range
Pipe size
Flow Range
GPM
LPM
1.5”
10
– 350
38
– 1,219
2.0”
20
– 550
76
– 2,082
2.5”
30
– 800
114
– 3,028
3.0”
50
– 1,250
189
– 4,731
4.0”
75
– 1,800
284
– 6,813
3” Single Check
Valve (SCV)
30 - 750
114
– 2,839
3” Dual Check Valve
(DCV)
30 - 750
114
– 2,839
Side mount (1/2 inch NPT)
200-2110-02-0
½ inch NPT threaded bushing to
mount from outside foam tank.
Bottom mount (1 inch NPT)
200-2100-04-0
1 inch NPT threaded bushing to
mount from outside foam tank
Top mount
200-2110-06-0
Extends from 2.5 feet to 5 feet
–
may be cut shorter if required.
Flow sensor weld fitting
Stainless steel
– 082-3060-00-0
Steel
– 309020
Aluminum - 309010
Flow sensor saddle clamp
2.0 inch
– 4842010
2.5 inch
– 4843010
3.0 inch
– 4844010
4.0 inch
– 4846010
Flow sensor paddlewheel
102714
Summary of Contents for SmartFOAM 1.7AHP
Page 3: ...Page 2 SmartFOAM NOTES...
Page 14: ...Page 13 SmartFOAM Figure 2 3 3 and 5 0 Foam Pump Installation Envelope Dimensions...
Page 15: ...Page 14 SmartFOAM SYSTEM DIAGRAM Figure 3 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Page 16: ...Page 15 SmartFOAM Figure 4 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Page 17: ...Page 16 SmartFOAM Figure 5 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Page 18: ...Page 17 SmartFOAM Figure 6 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Page 19: ...Page 18 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainer...
Page 20: ...Page 19 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Page 21: ...Page 20 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandIn lineStrainer...
Page 22: ...Page 21 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandFSSeriesStrainer...
Page 40: ...Page 39 SmartFOAM Figure 18 Typical 4 Inch Check Valve Installation Midship Pump...
Page 51: ...Page 50 SmartFOAM Figure 33 ADT Option Air Hose Connections Part 2...
Page 68: ...Page 67 SmartFOAM NOTES...
Page 80: ...79 Page 79 SmartFOAM NOTES...