3-37
To do…
Use the command…
Remarks
Configure the data
bits
databits
{
5 | 6 | 7
|
8
}
Optional
By default, the data bits of the
console port is 8.
Data bits is the number of bits
representing one character. The
setting depends on the contexts to
be transmitted. For example, you
can set it to 7 if standard ASCII
characters are to be sent, and set it
to 8 if extended ASCII characters are
to be sent.
Define a shortcut
key for enabling a
terminal session
activation-key
character
Optional
By default, you can press
Enter
to
enable a terminal session.
Define a shortcut
key for terminating
tasks
escape-key
{
default
|
character
}
Optional
By default, you can press
Ctrl+C
to
terminate a task.
Configure stop bits
detection
stopbit-error intolerance
Optional
By default, no stop bits are detected.
Configure the flow
control mode
flow-control
{
hardware
|
none
|
software
}
flow-control hardware
flow-control-type1
[
software
flow-control-type2
]
flow-control software
flow-control-type1
[
hardware
flow-control-type2
]
Optional
Configure the type
of terminal display
terminal type
{
ansi | vt100
}
Optional
By default, the terminal display type
is ANSI.
The device supports two types of
terminal display: ANSI and VT100. It
is recommended to set the display
type of both the device and the client
to VT100. If the device and the client
use different display types (for
example, hyper terminal or Telnet
terminal) or both are set to ANSI,
when the total number of characters
of the currently edited command line
exceeds 80, an anomaly such as
cursor corruption or abnormal
display of the terminal display may
occur on the client.
Configure the user
privilege level for
login users
user privilege level level
Optional
By default, the default command
level is 3 for the console user
interface.
Set the maximum
number of lines on
the next screen.
screen-length screen-length
Optional
By default, the next screen displays
24 lines.
A value of 0 disables the function.
Set the size of
history command
buffer
history-command max-size
value
Optional
By default, the buffer saves 10
history commands at most.
Summary of Contents for SR6600 SPE-FWM