examples fOr The funcTIOn cOOlIng and heaTIng:
example n1:
you have a heating system and want this system to keep a
temperature of 21°C with a hysteresis of 2°C. To do this you need to set T1 EIN
at 21°C and T1 AUS at 23°C. If the temperature gets to 21°C then the relay
will switch on. At 23°C it will switch off.
example n2:
you have a cooling system and want this system to keep a
temperature of 21°C with a hysteresis of 2°C. To do this you need to set T1 EIN
at 23°C and T1 AUS at 21°C. If the temperature gets to 21°C then the relay
will switch off. At 23°C it will switch on.