[8.I1]
E90 Error
chip-card-drive
(not all models)
=
„E90“
§ $ %
„HELP“ flashing.
Running machine is still functioning (except chip card function)
N
Communication malfunction with Chip-Card
N
Insert chip-card to the chip-card-drive
N
Replace chip-card
N
Replace chip-card-drive
N
Contact authorized service engineer
E91 Error
chip-card-drive
(not all models)
=
„E91“
§ $ %
„HELP“ flashing.
Running machine is still functioning (except chip card function)
N
Client number at START and STOP not identical.
N
Check chip-card
N
Insert the correct Chip-Card
E92 Error
chip-card-drive
(not all models)
=
„E92“
§ $ %
„HELP“ flashing.
Running machine is still functioning (except chip card function)
N
Too many training weeks
N
Check period of training
N
Check system date and time settings of the running machine
N
Re-program chip-card
E93 Error
chip-card-drive
(not all models)
=
„E93“
§ $ %
„HELP“ flashing.
Running machine is still functioning (except chip card function)
N
Test ident on the chip-card not accepted
N
False chip-card in the chip-card-drive
N
Insert the correct chip-card