trouble shooting
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
© 2008 h/p/cosmos sports & medical gmbh [email protected] created 01.09.2008 printed 08.10.2008 page: 118 of 176
[8.]
Trouble shooting
In case of any detected and/or assumed malfunctions and/or defects or unreadable safety warning
labels the device has to be taken out of operation, the device has to be marked and secured against
operation and the supplier and authorised service personnel has to be informed in writing. See „option
40“ in chapter „option settings“. With option 41 ... 44 you can lock also separate modes (manual,
profile, cardio, test).
[8.A]
Mechanical / Noise problems
In case you hear noises like knocking or rattling during the training please check if the machine has a firm stand and
follow exactly the advises in the chapter "Mechanical Installation" in this manual. Most time a false adjustment of the
levelling sockets (adjustable "feet") at the rear of the Running-Machine are responsible for the knocking sound.
[8.B]
Running belt adjustment problems
If the tension of the running belt is not correct it is difficult to keep the position of the belt centred.
In case of reverse direction of the running belt: It is normal that the belts needs to be re-adjusted every time when using
this option. Check and follow exactly the advises in the chapter "Control and Tightening of the Running Belt" in this
manual.
[8.C]
Fuses
Expulsion fuse / ON-OFF button 2-pole C16A
Expulsion fuse, device fuse 3-pole C16A
Secondary fuse isolation transformer 1-pole B16A
Secondary fuse isolation transformer 3-pole C16A