optional settings
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
© 2008 h/p/cosmos sports & medical gmbh [email protected] created 01.09.2008 printed 08.10.2008 page: 82 of 176
[6.A3]
Standard settings for the user options
[6.A3]
Option
Character / Function of option
Default setting
Adjustable range
OP 01
Set back of error messages
.
OP 02
Total distance (km)
Report only
0 ... 4.294.976 km
OP 03
Total hours of operation stand-by incl. runtime (h)
Report only
0 ... 1.193.046 h
OP 04
Total hours of operation runtime only (h)
Report only
0 ... 1.193.046 h
OP 05
Firmware Version
Report only
x.xx.x
OP 06
Adjustment of the real time clock
current date/time
currently ... 31.12.2092
OP 07
Acoustic Heart-Rate-signal
OFF
OFF or ON
OP 08
Stopping / Deceleration Time
5 seconds
2 ... 30 seconds
OP 09
Starting Speed (Modus Manual and Cardio)
0.5 km/h
0.0 km/h ... 5.0 km/h
OP 11
Scaling of Profile mode
0
0. 1 or 2
OP 12
Unit for display of speed – one decimal place rsp. none
for 3 = m/min
0 = km/h
0 = km/h 1 = m/s
2 = mph 3 = m/min
Unit for display of speed – two decimal places rsp.
none for 3 = m/min
20 = km/h 21 = m/s
22 = mph 23 = m/min
OP 13
Unit for display of distance
2: m
0: km;1: miles; 2: m
OP 14
Unit for angle of elevation
0: % (Prozent)
0 = % / 1 = ° (Grad)
OP 15
Subject's Body Weight
65 kg
10 ... 250 kg
OP 16
Request for body weight before manual or automatic
start
OFF (no request)
OFF / ON
OP 17
Unit for energy consumption
JOUL = kJoule
JOUL = kJoule
CALO = kcal
OP 18
Maximum speed (default) in Cardio mode
6.0 km/h
0.0 ... max. speed
OP19
Setting of Polar W:I:N:D System
0000 0000
xxxx xxxx
OP 20
RS 232 interface protocol: COM 1
1 = h/p/cosmos coscom
1 ... 20
OP 21
RS 232 interface protocol: COM 2
1 = h/p/cosmos coscom
1 ... 18
OP 23
RS 232 interface protocol: COM 4
20 = h/p/cosmos coscom v3
OFF,. 18,. 20, 22
OP 27
Minimum acceleration and deceleration level
1
1 ... 5
OP 28
Maximum acceleration and deceleration level
4
1 ... 7
OP 29
Acceleration and deceleration level for remote control
via RS232 interface
1 1
...
5
OP 40
Locking and unlocking the treadmill
ON (unlocked)
OFF = locked
ON = unlocked
OP 41
Locking and unlocking the Manual mode
ON (unlocked)
OFF = locked
ON = unlocked
OP 42
Locking and unlocking the Profile mode
6 (unlocked up to profile 6)
0 ... 6
OP 43
Locking and unlocking the Cardio mode
ON (unlocked)
OFF = locked
ON = unlocked
OP 44
Locking and unlocking the Test mode
28 (unlocked up to test 28)
0 ... 94
OP 45
Report mode Display „index“
0
0 … 3
OP 46
Report mode Display „elevation“
0
0 … 2
OP47
Sustain values in display resp. automatic „Reset“
OFF
OFF = RESET automat.
ON= RESET 2xSTOP
OP48 Count-Down
of
program-step
OFF
OFF = count-up
ON = count-down
OP 52
Output interval for printer protocol
60 (seconds)
0 = no single values,
1 ... 100
OP 53
Language settings for printer protocol
English
English, German,
French, Spanish
Portuguese, Hungarian