4.7.2 Line synchronization
This function synchronizes the output frequency to the frequency of the AC power source line. The output
frequency can be synchronized to power source line frequency (50 Hz/60 Hz).
Operation steps
Select
in the SET menu to select external synchronization mode, then set the sync signal source
to line synchronization (“LINE”).
1.
Perform the same operations as were described above for steps 2 to 5 in “
4.7.1 External signal
synchronization
” to select external synchronization mode, after which the external sync signal
source selection box will be displayed.
ENTER
CANCEL
Selection box
2.
Press the
or
key to move the cursor to “LINE”, the press the
EN TER
key.
This sets the external sync signal source to “LINE”.