4
ADVANCED OPERATION EXAMPLE
APS-1102A
4-35
1.
Open the SEQUENCE screen and display the PROGRAM screen.
See
“4.4.2 Sequence settings”
, for steps for displaying the PROGRAM screen.
2.
Press the
or
key to move the cursor to “TIME”.
ENTER
CANCEL
Cursor
3.
Press the
EN TER
key to display the modification box.
ENTER
CANCEL
Modification box
4.
Press the
and
keys to move the cursor to the digit to be changed, turn the MODIFY dial and
set a numerical value. The set value will be reflected in output immediately.
Increase
Decrease
5.
Use these steps to set all columns.
6.
After setting all of the columns, press the
CA NCE L
or
EN TER
key to close the modification box.