18 G503237E REV.3
3. Using the touch device, select the text
“port=”
and enter the
desired SIP protocol port
value (we
recommend using the
default 5060 port
)
4. Using the touch device, select the text “dtmf_open=” and enter the desired value, which will be the
same as that configured in the street panel
(1)
the
default value is =1
5. Using the touch device, select the text “dtmf_permanent_open=” and enter the desired value, which
will be the same as that configured in the street panel
(1)
the
default value is =0
6. Using the touch device, select the text “dtmf_close=” and enter the desired value, which will be the
same as that configured in the street panel
(1)
the
default value is =2
7. Configure the “Volume selection” to their default values:
- intercom_attenuation= 2
- intercom_mic_gain= -4.0
- door_mic_gain = -6.0
When all steps have been completed, press on the Save Configuration File option and continue the
setting with Data Network Settings in the next section
(1)
to complete the street panel setting refer to the corresponding 1 push button street panel installation guide from GUINAZ ELECTRONICA S.L
2.3.2.2
Data Network Settings
In order to configure the GUINAZ Smartive 7" monitor in the P2P mode (together with the rest of the
installation elements) it is necessary to set up the network parameters with an IP address static
configuration, following the process described.
On the installer setting screen select the “Connectivity” icon to access the Android settings and from there
access the network parameters.
Select “Conectivity”
icon and press