![GSi Autoflow 2000 Series Instruction Manual Download Page 49](http://html1.mh-extra.com/html/gsi/autoflow-2000-series/autoflow-2000-series_instruction-manual_2275079049.webp)
2000 Autoflow
49
Slave to Slave Interconnect
A second slave fan/heater unit can be added to op-
erate in unison with the master fan/heater unit and
another slave fan/heater unit. This would create a
three fan unit. The interconnect between the first
slave fan/heater unit and the second slave fan/heater
unit remains the same regardless of the type or pres-
ence of a control center. To wire a second slave fan/
heater unit to another slave fan/heater unit do the
following:
Figure 27: Wiring for a second slave fan/heater unit to another slave fan/heater unit.
ELECTRICAL POWER SUPPLY
NOTE: Do NOT use solid wire for inter-
connection.
1. Run four (4) 16ga MTW type wires
from the first slave fan/heater unit to
the second slave fan/heater unit.
2. Connect the wires as shown in figure
#27.
NOTE: A shielded 16 gauge cable is recommended
for use on the network connections. The network
connections for this configuration are attached to
terminals number 7 and 8 in slave #1 and terminals
number 3 and 4 in slave #2. Ground each end of
the shielded cable to the housing. A shielded 16
gauge 2 wire cable can be purchased from GSI.
Part #WR-16 / 2S
Slave #2 Fan and Heater Dipswitch Setting :
#1 and #2 - “Off” / All Others - “On”
Summary of Contents for Autoflow 2000 Series
Page 9: ...2000 Autoflow 9 Component Placement INSTALLATION...
Page 17: ...2000 Autoflow 17 INSTALLATION Close Up Detail of Grain Temperture Sensor Wiring...
Page 19: ...2000 Autoflow 19 Plenum hi limit installation INSTALLATION...
Page 22: ...2000 Autoflow 22 INSTALLATION Figure 6...
Page 24: ...2000 Autoflow 24 INSTALLATION Figure 7...
Page 27: ...2000 Autoflow 27 INSTALLATION Figure 9...
Page 29: ...2000 Autoflow 29 INSTALLATION Figure 10 3 00 ROOF MOUNT PLATE COMPRESSION COUPLER...
Page 31: ...2000 Autoflow 31 INSTALLATION Figure 11...
Page 39: ...2000 Autoflow 39 ELECTRICAL POWER SUPPLY Figure 18...
Page 45: ...2000 Autoflow 45 Figure 23 ELECTRIAL POWER SUPPLY...
Page 47: ...2000 Autoflow 47 ELECTRICAL POWER SUPPLY Autoflow to Ground Interconnect Figure 25...
Page 52: ...2000 Autoflow 52 ELECTRICAL POWER SUPPLY Figure 29...
Page 54: ...2000 Autoflow 54...