Liquid Propane (LP)
Top Dry dryers have internal vapor-
izers, and they are designed to oper-
ate on liquid draw from the supply
tank. Avoid using propane supply
tanks that have been used for vapor
draw for long periods of time. When
using liquid draw systems any mois-
ture that may be present in tanks or
lines may freeze when the system is
used in cold weather. To avoid this
situation, purge the system with
methanol. Do not use tanks which
have previously been used for am-
monia or fertilizer solutions. These
substances are extremely corrosive
and will damage fuel supply and
burner parts.
Because the vapor-
izer coil may need to be adjusted
during operation flexible hose suit-
able for LPs should be used for
the final field connection.
See the “Fuel Systems and
Rec-
LP line field connection.
Fuel System Specifications and Recommendations
Liquid Propane (LP)
ommendations Chart” for liquid propane to determine the correct size
line to run from the tank to the dryer. Have a qualified gas service per-
son inspect the installation to be sure that everything is installed accord-
ing to local codes and ordinances.
After installation is complete check all connections for leaks with
liquid detergent or comparable. Wear rubber gloves and eye protection.
Avoid contact with liquid propane. DO NOT USE FLAME FOR LEAK
TESTING.
INSTALLATION
Dryer
Fan Size
28
36”
40
42”
42”
Dryer
Horsepower
10-12
15
15
30
40
Maximum Heat
Capacity BTU
Per Hour
3 million
5 million
5.5 million
9 million
9.5 million
Maximum Fuel
Flow Gallons
Per Hour
32
54
60
95
104
Minimum
Line Size
1/2
1/2”
1/2”
1/2”
3/4”
Orifice
Size
1/4
21/64
11/32
.328”
29/64”
Minimum
Operating
Pressure
1 lb.
1 lb.
1 lb.
1 lb.
1 lb.
Maximum
Operating
Pressure
15 lbs.
15 lbs.
15 lbs.
15 lbs.
15 lbs.
Summary of Contents for Autoflow 2000 Series
Page 9: ...2000 Autoflow 9 Component Placement INSTALLATION...
Page 17: ...2000 Autoflow 17 INSTALLATION Close Up Detail of Grain Temperture Sensor Wiring...
Page 19: ...2000 Autoflow 19 Plenum hi limit installation INSTALLATION...
Page 22: ...2000 Autoflow 22 INSTALLATION Figure 6...
Page 24: ...2000 Autoflow 24 INSTALLATION Figure 7...
Page 27: ...2000 Autoflow 27 INSTALLATION Figure 9...
Page 29: ...2000 Autoflow 29 INSTALLATION Figure 10 3 00 ROOF MOUNT PLATE COMPRESSION COUPLER...
Page 31: ...2000 Autoflow 31 INSTALLATION Figure 11...
Page 39: ...2000 Autoflow 39 ELECTRICAL POWER SUPPLY Figure 18...
Page 45: ...2000 Autoflow 45 Figure 23 ELECTRIAL POWER SUPPLY...
Page 47: ...2000 Autoflow 47 ELECTRICAL POWER SUPPLY Autoflow to Ground Interconnect Figure 25...
Page 52: ...2000 Autoflow 52 ELECTRICAL POWER SUPPLY Figure 29...
Page 54: ...2000 Autoflow 54...