Plenum Temperature Sensor
The plenum temperature sensor is
the small grey PVC junction box at-
tached by a cord to the fan/heater
control box on the master fan/heater
unit.
1. On either side of the fan/heater,
drill one 3/4” hole even with the
fan/heater unit in a valley on the
bin sidewall.
2. Insert the probe through the
3/4” hole.
3. Position the housing so the cord
exits the housing horizontally,
and the tabs fall on the sidewall
peaks.
4. Use two self drilling screws to
mount the housing to the bin
sidewall.
5. Caulk between the housing and
the sidewall to seal.
Important!
If the Top Dry is a two fan unit,
do not mount the plenum tem-
perature sensor between the two
fan/heater units.
Plenum temperature sensor on the bin sidewall.
INSTALLATION
Summary of Contents for Autoflow 2000 Series
Page 9: ...2000 Autoflow 9 Component Placement INSTALLATION...
Page 17: ...2000 Autoflow 17 INSTALLATION Close Up Detail of Grain Temperture Sensor Wiring...
Page 19: ...2000 Autoflow 19 Plenum hi limit installation INSTALLATION...
Page 22: ...2000 Autoflow 22 INSTALLATION Figure 6...
Page 24: ...2000 Autoflow 24 INSTALLATION Figure 7...
Page 27: ...2000 Autoflow 27 INSTALLATION Figure 9...
Page 29: ...2000 Autoflow 29 INSTALLATION Figure 10 3 00 ROOF MOUNT PLATE COMPRESSION COUPLER...
Page 31: ...2000 Autoflow 31 INSTALLATION Figure 11...
Page 39: ...2000 Autoflow 39 ELECTRICAL POWER SUPPLY Figure 18...
Page 45: ...2000 Autoflow 45 Figure 23 ELECTRIAL POWER SUPPLY...
Page 47: ...2000 Autoflow 47 ELECTRICAL POWER SUPPLY Autoflow to Ground Interconnect Figure 25...
Page 52: ...2000 Autoflow 52 ELECTRICAL POWER SUPPLY Figure 29...
Page 54: ...2000 Autoflow 54...