![GSi Autoflow 2000 Series Instruction Manual Download Page 21](http://html1.mh-extra.com/html/gsi/autoflow-2000-series/autoflow-2000-series_instruction-manual_2275079021.webp)
2000 Autoflow
21
INSTALLATION
Wet Supply Rotary Switch
1)
Drill a 2” diameter hole through the
hopper bottom.
If a flat bottom bin is being
used for a wet storage tank the
Wet Supply Rotary Switch
would be mounted 45 degrees
up the sidewall from the center
of the bin. Example: If the wet
storage bin is 18’ in diameter
then the Wet Supply Rotary
Switch would be mounted 9’
up the sidewall.
2)
If the bin is 2.66” corrugation the hole
should be centered on an outside hill.
3)
If the bin is 4.00” corrugation the hole
should be centered on an outside
valley.
4)
Use the mounting plate as a pattern
and drill four 3/8” holes through the
sidewall at the swich location so the
place can be bolted to the bin.
5)
Add foam weather strip around the top
and side of the mounting plate.
6)
Caulk the underside of the mounting
plate, on all sides of the 2” hole, and
where the plate meets the bin.
7)
Bolt the mounting plate to the
sidewall.
8)
Attach the flex coupling to the rotary
switch power pack using a roll pin.
9)
Attach the 1-vane paddle to the flex
coupling as shown in figure 6.
10) Apply teflon tape or pipe sealant (not
included) to the rotary switch power
pak threads and thread the rotary
switch power pack into the mounting
plate coupling.
11) Make sure that the conduit hole is
facing down or is horizontal.
Wet Supply Rotary Switch Mounted on Wet Supply Tank
Summary of Contents for Autoflow 2000 Series
Page 9: ...2000 Autoflow 9 Component Placement INSTALLATION...
Page 17: ...2000 Autoflow 17 INSTALLATION Close Up Detail of Grain Temperture Sensor Wiring...
Page 19: ...2000 Autoflow 19 Plenum hi limit installation INSTALLATION...
Page 22: ...2000 Autoflow 22 INSTALLATION Figure 6...
Page 24: ...2000 Autoflow 24 INSTALLATION Figure 7...
Page 27: ...2000 Autoflow 27 INSTALLATION Figure 9...
Page 29: ...2000 Autoflow 29 INSTALLATION Figure 10 3 00 ROOF MOUNT PLATE COMPRESSION COUPLER...
Page 31: ...2000 Autoflow 31 INSTALLATION Figure 11...
Page 39: ...2000 Autoflow 39 ELECTRICAL POWER SUPPLY Figure 18...
Page 45: ...2000 Autoflow 45 Figure 23 ELECTRIAL POWER SUPPLY...
Page 47: ...2000 Autoflow 47 ELECTRICAL POWER SUPPLY Autoflow to Ground Interconnect Figure 25...
Page 52: ...2000 Autoflow 52 ELECTRICAL POWER SUPPLY Figure 29...
Page 54: ...2000 Autoflow 54...