2000 Autoflow
44
ELECTRIAL POWER SUPPLY
Autoflow to Drying Chamber Rotary Switches Interconnect
The three (3) 110V AC rotary switches located
in the drying chamber are used to inform the
computer on the location of grain in the drying
chamber. The rotary switch with the shortest
extension is the Drying Chamber Overflow Rotary
Switch. It is used as a safety in the event the
Chamber High Level Rotary Switch fails. The
rotary switch with the longest extension is the Drying
Chamber Low Level Rotary Switch. It is used to
inform the computer when the peak has been
covered with grain so the drying process can begin;
and, will shut the dryer down if the drying chamber
empties unexpectedlly. The third rotary switch is
the Drying Chamber High Level Rotary Switch. It
is used to inform the dryer when the drying chamber
is full. The Drying Chamber Rotary Switches us
110V AC to power the motor and 12V DC+ to
switch a signal back to the computer. The 110V
AC, 110V N, and the 12V DC+ wires can be
jumped from rotary switch to rotary switch to lessen
the wires needed.
To wire the Drying Chamber Rotary
Switches to the Autoflow Control Box do the
following:
1)
Run six (6) control wires from the
Autoflow Control Box to the Drying
Chamber Rotary Switches.
2)
Connect the wires as shown in figure 23.
Summary of Contents for Autoflow 2000 Series
Page 9: ...2000 Autoflow 9 Component Placement INSTALLATION...
Page 17: ...2000 Autoflow 17 INSTALLATION Close Up Detail of Grain Temperture Sensor Wiring...
Page 19: ...2000 Autoflow 19 Plenum hi limit installation INSTALLATION...
Page 22: ...2000 Autoflow 22 INSTALLATION Figure 6...
Page 24: ...2000 Autoflow 24 INSTALLATION Figure 7...
Page 27: ...2000 Autoflow 27 INSTALLATION Figure 9...
Page 29: ...2000 Autoflow 29 INSTALLATION Figure 10 3 00 ROOF MOUNT PLATE COMPRESSION COUPLER...
Page 31: ...2000 Autoflow 31 INSTALLATION Figure 11...
Page 39: ...2000 Autoflow 39 ELECTRICAL POWER SUPPLY Figure 18...
Page 45: ...2000 Autoflow 45 Figure 23 ELECTRIAL POWER SUPPLY...
Page 47: ...2000 Autoflow 47 ELECTRICAL POWER SUPPLY Autoflow to Ground Interconnect Figure 25...
Page 52: ...2000 Autoflow 52 ELECTRICAL POWER SUPPLY Figure 29...
Page 54: ...2000 Autoflow 54...