52
Program description: basic settings – model helicopter
(Collective) pitch min
stick mode
rotor direct
swashplate
1
left
3sv(2roll)
SEL
pitch min
front
At this point you can set up the direction of operation of
the throttle / collective pitch stick to suit your preference:
press the rotary cylinder briefl y, then use the rotary
cylinder to select the appropriate setting. This setting is
crucial to the correct operation of all the other options
in the helicopter program which affect the throttle and
collective pitch functions, i. e. the throttle curve, idle trim,
tail rotor mixer etc..
Pitch
The meaning is as follows:
“front”: minimum collective pitch when the collective
pitch stick (Ch 1) is “forward” (away from you);
“rear”:
minimum collective pitch when the collective
pitch stick (Ch 1) is “back” (towards you).
Pressing
CLEAR
sets the collective pitch min. position
to “forward”.
Note:
The Ch 1 trim always affects the throttle servo only.
•
By default what is known as the “throttle limiter” is set
•
(see page 62); this limits the travel of the throttle ser-
vo in the direction of maximum throttle, acting sepa-
rately from the collective pitch servos. This point can
be programmed using the “
Lim
” input in the »
contr
set.
« menu.
Timers
Two timers are shown in the basic display: one stop-
watch and one fl ight timer.
STARLET
#02
5:36h
stop
flt
«normal »
K78
IFS
0:00
0:00
9.6
V
A physical switch or a control switch – e. g. the control
switch C3 located on the throttle limiter – can be as-
signed to these two timers in the “timers” line …
rotor direct
swashplate
left
3sv(2roll)
pitch min
0:00
SEL
SEL
clock
front
… using the switch symbol on the right-hand side. The
assigned switch starts both timers, and also halts the
stopwatch.
The method of assigning a physical switch or a control
switch is described on page 33.
The fl ight timer always starts simultaneously with the
stopwatch, but continues to run even when the stop-
watch is halted (switched off). It can only be stopped by
pressing
ESC
with the stopwatch halted.
Once stopped, pressing
CLEAR
resets both timers to
the initial value.
Switching between “count-up” and “count-down”
Count-up timer (stopwatch function)
If you assign a switch and start the stopwatch with the
initial value of “0:00”, the timer runs up until the maxi-
mum of 999 minutes and 59 seconds, then re-starts at
0:00.
Count-down timer (alarm timer function)
You can use the left-hand
SEL
fi eld to select a start-
ing time within the range 0 to 180 minutes; using the
right-hand
SEL
fi eld the range is 0 to 59 seconds. Any
combination of times can also be selected.
(
CLEAR
= “0” or “00”.)
rotor direct
swashplate
left
3sv(2roll)
pitch min
clock
front
10:01
SEL SEL
C3
Procedure
Select the
1.
SEL
fi eld with the rotary cylinder.
Press the rotary cylinder.
2.
Select the required time in the highlighted minutes
3.
and seconds fi elds using the rotary cylinder.
Press the rotary cylinder to conclude the input pro-
4.
cess.
Once you have switched back to the basic display, press
the
CLEAR
button fi rst with the stopwatch halted, so
Summary of Contents for mx-16 ifs
Page 1: ...mx 16 Programming Manual mx 16iFS 1 gb 3D CYLINDER ROTARY SELECT INTELLIGENT FREQUENCY SELECT...
Page 15: ...15 For your notes...
Page 31: ...31 For your notes...
Page 35: ...35 For your notes...
Page 39: ...39 For your notes...
Page 55: ...55 For your notes...
Page 65: ...65 For your notes...
Page 77: ...77 For your notes...
Page 104: ...104 For your notes...
Page 111: ...111 For your notes...
Page 128: ...128 For your notes 128...
Page 129: ...129 For your notes 129...
Page 130: ...130 For your notes...