Error Handling
In the event of an error that stops electrostatics
output, the events shown by the timing diagram
below must occur.
It is recommended that the Safe-to-Move output be
used to tell the remainder of the system that it is ok
to begin painting again.
REMOTE Enable/Disable
Input
All Interlocks
Electrostatic Enable Input
Error Reset
Error Output
Electrostatics
Safe-to-Move Output
Electrostatic Discharge
Output
Fluid Supply*
Part Conveyor*
Applicator Movement*
A: Hold high until error output is low
B: Fix error condition
t
C1
: Time as set by parameter t
C1
t
C2
: Time as set by parameter t
C2
* Not controlled by electrostatic controller
333266D