Pre-Installation Steps
Ventilate the Spray Booth
Provide fresh air ventilation to avoid the buildup of
flammable or toxic vapors when spraying, flushing,
or cleaning the gun. Do not operate the gun unless
ventilation fans are operating.
Electrically interlock the controller (B) with the
ventilators to prevent gun operation without
ventilating fans operating. Use the 24 VDC Interlock
pin on the Discrete I/O cable to connect to the
ventilator interlock. Check and follow all National,
State, and Local codes regarding air exhaust velocity
requirements.
NOTE: High velocity air exhaust will decrease the
operating efficiency of the electrostatic system. The
minimum allowable air exhaust velocity is 60 ft/minute
(19 linear meters/minute).
Install the Pro Xpc Auto Spray Gun
See the Pro Xpc Auto Air Spray Gun Manual
(332992) for installation instructions.
Interlock Waterborne Isolation
Enclosure
To reduce the risk of electric shock, interlock the
controller with the voltage isolation system to shut
off the electrostatics anytime the isolation system
enclosure is opened.
For information about the interlocks and their use,
see
.
12